8
SERIAL COMMUNICATION PROTOCOL
SERIAL COMMUNICATION PROTOCOL
Command Description Response
RMA:a? Read Input A Remote Conguration RMA:a,b,c,d,e,f,g,h
G = Automation Tally Input Status
H = Tally Back Input Status
RMB:a,b,c,d,e,f Congure Input 2 Remotes ACK:
See RMA: function for details
RMB:a? Read Input B Remote Conguration RMB:a,b,c,d,e,f,g,h
RST: Reset Mixer
SER: Unit Serial Number SER:x
SFD: Sets unit to Factory Defaults and reboots
SRQ:? Status Request SRQ:data
TAL:a,b,c,d,e Tally Control ACK:
A = Channel number.
1 = Ch 1
2 = selects Ch 2
etc
a = selects Ch 10
B = Input 1 Tally Back
1 = Active Tally
0 = Inactive Tally
C = Input 2 Tally Back
1 = Active Tally
0 = Inactive Tally
D = Input 1 Auto Tally
1 = Active Tally
0 = Inactive Tally
E = Input 2 Auto Tally
1 = Active Tally
0 = Inactive Tally
TAL:a? Read Tally Input Status TAL:a,b,c,d,e;
A = Channel number. (see above)
TBK:a,||b,c,d Congure Talkback ACK:
A = Button Control
1 = on
0 = o
B = Mix / Cut into Guest Headpones
1 = Cut
0 = Mix
C = Talkback Source
1 = Channel 1 Line
0 = Channel 1 Mic
D = Talkback Permanently Routed to Talkback Connector
1 = Always Routed
0 = Only routed when a T/B button is pressed